wechat
d3f465e7-84e5-42bb-9e8a-045675d7acbb.webp1
whatsapp
736c7497-0c03-40d4-ba30-fc57be1a5e23.webp1
mailto
up

Feature Products

We Provide
High Quality product

Emergency Rescue Equipment

EXCAVATOR

EXCAVATOR

Lorem ipsum dolor sit amet, consectetur adipisicing elit,
sed do eiusmod

life line life jacket

life line life jacket

fire pump

fire pump

rubber fire hose reel

rubber fire hose reel

fire jockey pump

fire jockey pump

fire fighting water pumps for sale

fire fighting water pumps for sale

airhead life vest

airhead life vest

About Us

About Us

pressure fire hose

Ultra-Remote High Pressure Fire Water Pump With Lighting I first saw this unit during a night drill on a windy ridge, where the ground crew had only headlamps and grit. The pump started on the first pull, the LED floods cut through the smoke, and — to be honest — that’s when I decided to dig into it properly. Built in No.118 Youyi Street, Xinhua Dist., Shijiazhuang City, Hebei Province, China, the kit comes complete: engine, pump, spray gun, inlet pipe, high‑pressure hose, and all the sensible accessories. The engine uses a direct-connection design, which matters more than marketing copy suggests — fewer losses, fewer things to shake themselves loose. What’s driving demand (and why lighting is non‑negotiable) Wildland–urban interface fires, longer hose lays, and night operations are the new normal. Agencies want portable, high-pressure pumps that can push water hundreds of meters uphill and still be light enough to move between drop points. Integrated lighting is no longer a “nice-to-have”; it’s scene safety. Many customers say they’ve ditched separate light towers because an onboard LED array is simpler and faster. Technical snapshot Pump type High-pressure centrifugal, direct-coupled Rated flow/pressure ≈ 150–220 L/min @ 0.8–1.2 MPa (real‑world use may vary) Max head ≈ 110–130 m Engine options 4‑stroke gasoline/diesel, ≈ 8–20 hp, electric or recoil start NPSHr ≈ 3–3.5 m at Qrated Lighting module IP65 LED floodlight, ≈ 3,000–6,000 lm, tilt-adjust Noise ≤ 86 dB(A) @ 7 m (≈ 75% load) Runtime ≈ 2.5–4 h @ 75% load (tank size dependent) Hose kit High‑pressure layflat 1"–1.5", 100–400 m options Use cases: wildland booster lines, long-distance relay, remote villages, mining benches, tunnel works, port yards. Advantages: quick-deploy frame, corrosion‑resistant hardware, integrated lighting, low vibration, intuitive controls. How it’s built and tested (short version) Materials: hard‑anodized aluminum pump body, stainless 316 fasteners, bronze wear rings, Viton® seals; powder‑coated steel frame. Methods: CNC‑machined impeller, dynamic balancing, TIG‑welded frame, salt‑spray verification ≈ 240 h. Testing: hydrostatic proof test at 1.5× rated pressure; performance mapping per EN 1028 and GB 6245; engine power checked to ISO 15550. Typical service life: 8–12 years with annual maintenance. Field test notes Factory bench (20°C): 1.2 MPa at 170 L/min, fuel 0.9–1.2 L/h, start time Cold start trial: −10°C with ether‑free protocol, pass x3 cycles. LED module: ≈ 5,000 lm; 8 h continuous on auxiliary battery pack. Vendor comparison (quick take) Vendor Certs/Standards Lead time Warranty Lighting FFW Firesafety ( Ultra-Remote High Pressure Fire Water Pump With Lighting ) EN 1028, GB 6245 tested; ISO 9001 plant; CCCF options ≈ 2–4 weeks 12–24 months Integrated IP65 LED Generic import Mixed; limited test data ≈ 6–10 weeks 6–12 months Add‑on only Local assembly Varies by shop ≈ 1–3 weeks Shop policy Custom fit Customization and accessories Engines: gasoline vs. diesel; recoil or electric start with battery. Lighting: 3,000–6,000 lm, spot/flood optics, 360° mast option. Hoses/couplings: 1"–1.5", Storz/NH/NPT; hose lengths up to 400 m. Skid or backpack frames; anti‑vibration feet; tool‑less filter service. Telemetry: pressure/flow logging, geo‑tagged run hours (on request). Brief case notes Mining bench, Inner Mongolia: two units in relay cut setup time by ≈ 35% and held 1.0 MPa at 280 m elevation gain. Winery estate, WUI line defense (Australia): one Ultra-Remote High Pressure Fire Water Pump With Lighting ran 3.2 h on a single tank feeding 3 nozzles; crews praised the onboard lighting for safe pack-up at 2 a.m. “Surprisingly quiet,” one operator said. If you’re speccing for municipal boosters, forestry attack, or remote industrial sites, this is a solid, field-proven package. Demo and shipping from the origin listed above; global documentation available on request. Authoritative citations EN 1028-1/2: Firefighting pumps — Safety and performance requirements. GB 6245: Fire pumps — Performance test methods (China). ISO 15550: Internal combustion engines — Determination of net power. NFPA 20: Standard for the Installation of Stationary Pumps for Fire Protection (context for pump performance/acceptance).

FAQS An emergency firefighting equipment that's right for you

How about ODM?

Our company have an R&D team, they can learned how to make the pump according to the drawing you offer. Our company have an R&D team, they can learned how to make the pump according to the drawing you offer.
Our company have an R&D team, they can learned how to make the pump according to the drawing you offer.

How about sample policy?

We can give you a competitive price for the sample, the shipping fee will be at the client’s side. We can give you a competitive price for the sample, the shipping fee will be at the client’s side.
We can give you a competitive price for the sample, the shipping fee will be at the client’s side.

What’s the guarantee period?

One year after the shipping date. But except the wearing parts(shaft, impeller, seal), meanwhile if need we will send some wearing parts for your convenience. One year after the shipping date. But except the wearing parts(shaft, impeller, seal), meanwhile if need we will send some wearing parts for your convenience.
One year after the shipping date. But except the wearing parts(shaft, impeller, seal), meanwhile if need we will send some wearing parts for your convenience.

Common Failures and methods?

Failure: Pumps have abnormal vibration and noise Methods: A: Repair water piping                   B: Increasing the water piping                   C: Irrigation fluid, to exclude air                   D: Improve the system or re-section                   E: Maintenance pump Failure: Pumps have abnormal vibration and noise Methods: A: Repair water piping                   B: Increasing the water piping                   C: Irrigation fluid, to exclude air                   D: Improve the system or re-section                   E: Maintenance pump
Failure: Pumps have abnormal vibration and noise Methods: A: Repair water piping B: Increasing the water piping C: Irrigation fluid, to exclude air D: Improve the system or re-section E: Maintenance pump

After-sale Service

Supplied professional technical guide free of charge at anytime. Supplied professional technical guide free of charge at anytime.
Supplied professional technical guide free of charge at anytime.
faq faq faq
 News

News

Latest News About Our Company

jockey fire fighting pump

2026-04-09 09:46

jockey fire fighting pump

A jockey fire fighting pump is an essential component in high-performance fire protection systems. Unlike main fire pumps that activate during emergencies, jockey pumps maintain pressure in the system, ensuring readiness at all times. By keeping the system pressurized, they help prevent false alarms, reduce start-ups for larger pumps, and maintain overall system integrity. To fully appreciate why
forest fire fighting equipment supplies

2026-04-09 08:25

forest fire fighting equipment supplies

The realm of forest fire fighting is one of unparalleled challenge and importance, demanding equipment that can withstand the harshest conditions while delivering peak performance. As wildfires continue to increase in frequency and intensity across the globe, the need for advanced forest fire fighting equipment and supplies has never been more critical. Understanding the intricacies of these tools
fire hydrant system pumps

2026-04-09 08:04

fire hydrant system pumps

Navigating the vast landscape of fire safety solutions can be a daunting task, with a multitude of options and systems available. Yet, when it comes to ensuring the utmost safety and protection from fires, the fire hydrant system pump stands as a critical component in commercial and residential settings alike. This article delves into the technical prowess, expertise, and reliability of fire hydra

SUBSCRIBE NEWSLETTER

We are very interested in your company's high-quality fire protection equipment and hope to learn more about the products and discuss purchasing matters.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


en_USEnglish